Kuhnke FIO 
Counter-Posi2 5V-24V
        
        
          694 454 01
          
      
    
  The Kuhnke FIO Counter module counts binary pulses and transmits the meter readings electrically isolated to the master control. There are 2 counters. The module can operate as A-B-Ref or forward/backward counter. It can be switched between single and multiple evaluation of the encoder signals. The digital inputs and the output can be used in normal operation as digital I/O with control and status indications via the bus. Through an appropriate configuration can the output also be controlled in dependence of a counter. In addition, input signals can be used to delete, initialize or freeze the meter readings. The Counter/Posi module also offers 2 analogue outputs which can be used to output a position-dependent analog value in the range of -10 to +10 V DC.
- Store, lock, set counter
 - 24 V up/down counter (32 bit)
 - 8 x DI 1ms, 2 x incremental encoder 200 kHz (A, B, Ref-Z)
 - 2 x DO 2A, 2 x AO -10 ... +10V (12 bit)
 
Technical details
| Description | Value | 
|---|---|
| Function | Counter | 
| Model | Control cabinet modul | 
| Digital I/Os (integrated) | inputs: 8 DI 1ms, 2 incremental encoders 200kHz / outputs: 2 DO 2A | 
| Analogue I/Os (integrated) | outputs: 2 AO -10..+10V 12Bit | 
| Interfaces | A, B, Ref-Z | 
| Product status | Standard product | 
| Field bus interfaces | EtherCAT | 
| Type of connection | female plug with PUSH IN spring connection | 
| Status indication | EtherCAT Status, LEDs allocated to the point of termination | 
| Housing material | Aluminium frame, plastic housing | 
| Dimensions (W x H x D) | 25 x 120 x 90 mm | 
| IP-Protection Class | IP 20 | 
| Supply voltage | 24 V (-15% / +20%) | 
| Operating temperature | 0 ... +55°C | 
| Immunity | Zone B according to EN 61131-2 | 
| Certifications | CE,UL |